Electromechanical swing 1 door installation
The installation procedure is displayed at the startup of the system only if it has not been previously installed.
Starting the System
Power the system
NOTE: Ensure all connections have been made correctly before initializing the system
Select Language
LANGUAGE |
Press the RIGHT or LEFT button to choose the desired language, then press ENTER to confirm. |
Set 1 Motor
Press ESC
to exit the guided setup mode.
Navigate through the menu to SYSTEM MENU -> NUM. MOTORS
and set the value to 1
Then restart the system (disconnect and reconnect the power) to continue with the installation.
Motor Check
Now verify the correct connection of the motor
The following command will appear on the display. Perform the described procedure.
OPEN DIRECTION SETUP |
While holding down the PP (Step-by-Step) button or the associated remote control button, gate M1 (leaf) should move to an opening position. Upon releasing the PP button or the remote control, the gate's direction will be opposite to the previous one. |
NOTE: If the direction of a leaf is incorrect (opening first and then closing is the correct direction), reverse the motor phases associated with that leaf.
The correct operation cycle is shown below
```mermaid sequenceDiagram participant A as Opening participant C as Closing A->>A: Holding down the START button loop Operation cycle activate A Note left of A: Opening in progress deactivate A Note left of A: Release the button A->>C: Holding down the START button activate C Note right of C: Closing in progress deactivate C Note right of C: Release the button C->>A: Holding down the START button end
Once the correct operation has been verified, bring the gate leaf to the halfway point
Is the motor not moving?
Set the force values
It may be necessary to increase the force values.
In this case, press the ENT
button and set the following parameters.
ADVANCED MENU -> FORCE M1 |
Set the force value for motor M1 |
Then turn off and turn on the control unit again to return to programming mode.
Press the ENT
button
The control unit now asks for confirmation to start the automatic learning process.
Press the ENT
button to start.
Press the ESC
button to cancel.
At this point, the control unit initiates an opening maneuver followed by a closing maneuver.
In this way, it learns the working times of the gate.
CAUTION!: During this phase, the obstacle detection is disabled.
Ensure there are no obstacles within the gate's range of action during the entire procedure.
The installation procedure is completed. However, it is possible to manually change the operating logics via the Menus
End-of-Travel Stops
If there are end-of-travel stops in the system, follow the guide below
End-of-Travel Stops in Opening
If the system includes opening end-of-travel stops, set the parameters as follows
Plant Menu -> FCA1/FCA2 |
PRESENT |
End-of-Travel Stops in Closing
If the system includes closing end-of-travel stops, set the parameters as follows
Plant Menu -> FCC1/FCC2 |
PRESENT |