Hydraulic swing 2 door installation
The installation procedure is displayed at the startup of the system only if it has not been installed yet.
Start the System
Power up the system
NOTE: Ensure all connections have been made correctly before initializing the system
Select Language
LANGUAGE |
Press the RIGHT or LEFT button to choose the desired language, then press ENTER to confirm. |
Check Motors
Now verify the correct connection of the motors
The following command will appear on the display. Carry out the described procedure.
DIRECTION OPEN TO INSTALL |
By holding down the PP (Step-by-Step) button or the button on the associated remote control, the M1 gate (leaf) should move by performing an opening. Following the set offset, the M2 gate (strike) should then move. Upon releasing the PP button or the remote control, the direction of the gates will be opposite to the previous one. |
NOTE: If the direction of a gate is not correct (the correct direction is opening and then closing), reverse the motor phases associated with that gate.
The correct cycle of operation is described below
```mermaid sequenceDiagram participant O as Opening participant C as Closing O->>O: I press and hold the START command loop Operating Cycle activate O Note left of O: Opening in progress deactivate O Note left of O: I release the button O->>C: I press and hold the START command activate C Note right of C: Closing in progress deactivate C Note right of C: I release the button C->>O: I press and hold the START command end
Once the correct operation has been verified, bring the gates to mid-travel
The motors are not moving?
Set the force values
It may be necessary to increase the force values.
In this case, press the ENT
button and set the following parameters.
ADVANCED MENU -> FORCE M1 |
Set the force value for motor M1 |
ADVANCED MENU -> FORCE M2 |
Set the force value for motor M2 |
Then turn off and on the control unit to return to programming mode.
Press the ENT
button
The control unit now requires confirmation to start the automatic learning process.
Press the ENT
button to start.
Press the ESC
button to cancel
At this point, the control unit sets the working times to 60 seconds.
Manual Setting of Parameters
Set SYSTEM MENU -> ELECTROMECHANICAL MOTOR = HYDRAULIC
Then set the working times via ADVANCED MENU -> WORK TIME M1
ADVANCED MENU -> WORK TIME M2
WARNING!: During this phase, the obstacle detection is disabled.
Ensure there are no obstacles within the gate's range of action during the entire procedure.
The installation procedure is completed. However, it is possible to manually change the operating logic via the Menus
End of Travel Stops
If present in the system, follow the guide below
End of Travel Stops in Opening
If the system includes end of travel stops in the opening, set the parameters as follows
System Menu -> FCA1/FCA2 |
PRESENT |
End of Travel Stops in Closing
If the system includes end of travel stops in closing, set the parameters as follows
System Menu -> FCC1/FCC2 |
PRESENT |