Logic
The control unit incorporates a 4-way Dip-switch with which it is possible to change some operating parameters.
DIP | Function | Description |
---|---|---|
1 ON 2 OFF |
Opening Logic | - Remote Opening The PP command or radio command performs an opening. Only when the gate is completely open can a closing command be executed |
1 OFF 2 ON |
Opening Logic | - Open-Stop-Close-Stop The PP command or radio command performs an opening. If a new command is given while opening, a STOP is performed. If pressed again, it will perform a closing. |
1 ON 2 ON |
Opening Logic | - Commonhold The PP command or radio command performs an opening. Only when the gate is completely open will it close automatically after the pause time expires. |
3 OFF | Water Hammer | - Disabled |
3 ON | Water Hammer | - Enabled: At each opening, only when the gate is completely closed, a brief closure is performed to facilitate the unlocking of the electric lock. |
4 OFF | LAMP Pre-Alert | - Disabled: The flashing light turns on simultaneously with the start of the maneuver. |
4 ON | LAMP Pre-Alert | - Enabled: The flashing light turns on 2.5s before the maneuver. |