Logic

The control unit incorporates a 4-way Dip-switch with which it is possible to change some operating parameters.

DIP Function Description
1 ON
2 OFF
Opening Logic - Remote Opening
The PP command or radio command performs an opening.
Only when the gate is completely open can a closing command be executed
1 OFF
2 ON
Opening Logic - Open-Stop-Close-Stop
The PP command or radio command performs an opening.
If a new command is given while opening, a STOP is performed.
If pressed again, it will perform a closing.
1 ON
2 ON
Opening Logic - Commonhold
The PP command or radio command performs an opening.
Only when the gate is completely open will it close automatically after the pause time expires.
3 OFF Water Hammer - Disabled
3 ON Water Hammer - Enabled:
At each opening, only when the gate is completely closed, a brief closure is performed to facilitate the unlocking of the electric lock.
4 OFF LAMP Pre-Alert - Disabled:
The flashing light turns on simultaneously with the start of the maneuver.
4 ON LAMP Pre-Alert - Enabled:
The flashing light turns on 2.5s before the maneuver.