Menu base
DISPLAY | DESCRIPTION |
---|---|
USCITA LAMP |
- CONTINUOUS LAMP OUTPUT: Use a flashing light with integrated self-flashing circuit - INTERMITTENT LAMP OUTPUT: The control unit simulates flashing on a normal lamp |
ELETTROSERRATURA |
From 0 to 6 s ELECTRIC LOCK ACTIVATION TIME expressed in seconds (0 = DISABLED) |
CH AUTO |
- AUTO CLOSE ENABLED: Activates automatic closing after the pause time expires - AUTO CLOSE DISABLED: Disables automatic closing |
TEMPO PAUSA |
This entry is available only if CH AUTO is enabledPAUSE TIME settable from 0 to 120 s: Pause time before automatic closing |
FOTO & TP |
This entry is available only if CH AUTO is enabled- FOTO & TP ---: When the gate is stationary and in the fully open position (or pedestrian opening) the interruption on the photocell resets the pause time to the value set in the TEMPO PAUSA menu- FOTO & TP 5s: when the gate is stationary and in the fully open position (or pedestrian opening) the interruption on the photocell sets the pause time to 5s. |
SFAS. CHIUSURA M1 |
CLOSING DELAY M1 (from 0s to 15s): Defines the delay during closing between the two gates to avoid their overlapping. During closing, the M1 leaf (swing) moves later compared to the M2 leaf (fixed) according to the set time. At 0s the delay is disabled. |
RALLENTAMENTO |
SLOWDOWN: Duration of the slowdown (from 0 to 25% of WORK TIME M1 and WORK TIME M2 )At 0 the slowdown is disabled (not recommended) |
COSTA SENSIBILE |
- SENSITIVE EDGE NC: Mechanical type with normally closed contact. - SENSITIVE EDGE 8K2: Resistive type 8k2ohm Only during the closing movement of the gate, activation by the sensitive edge causes a brief reversal of direction (lasting 1s) to clear the obstacle. |