| 1, 3 |
F - N |
Power supply 230 V AC ± 10% (50-60Hz) |
| - |
GND |
Ground connection |
| 4, 5 |
LAMP |
Flashing light output 230 V AC |
| 11 |
CH |
Closing output for gate motor M2 (fixed leaf) |
| 10 |
COM |
Common output for gate motor M2 (fixed leaf) |
| 9 |
AP |
Opening output for gate motor M2 (fixed leaf) |
| 8 |
CH |
Closing output for gate motor M1 (swing leaf) |
| 7 |
COM |
Common output for gate motor M1 (swing leaf) |
| 6 |
AP |
Opening output for gate motor M1 (swing leaf) |
| 12, 13 |
LC |
Courtesy light output 230 V AC |
| 21 |
ES |
Electric lock output 12 V AC |
| 22 |
0 V |
Reference potential output 0 V |
| 24 |
24 V |
Power supply output + 24 V DC |
| 25 |
SCA |
Open gate indicator output 24 V |
| 26 |
PP |
Step-by-step control input (NO) |
| 27 |
STP |
Stop control input (NC) |
| 30 |
APP |
Partial opening control input |
| 31 |
FOT1 |
External photocell input 1 (NC) |
| 34 |
FOT2 |
Internal photocell input 2 (NC) |
| 35 |
SC |
Sensitive edge (NC or 8k2) |
| 36 |
0 V |
Reference potential output (0 V) |
| 32 |
TMR |
External timer input (NO) |
| 46 |
AUX1 |
Safety input during opening (NC) |
| 47 |
0 V |
Reference potential output 0 V |
| 48 |
CK |
Power supply output for photocell check (+ 24 V DC) |
| 43, 44 |
CH2 |
Second channel radio output |
| 42, 41 |
ANT |
Antenna connection |
|
FC-EN |
End-of-travel module connector |
|
RADIO |
Radio Module |