1, 3 |
F - N |
Power supply 230 V AC ± 10% (50-60Hz) |
- |
GND |
Ground connection |
4, 5 |
LAMP |
Flashing light output 230 V AC |
11 |
CH |
Closing output for gate motor M2 (fixed leaf) |
10 |
COM |
Common output for gate motor M2 (fixed leaf) |
9 |
AP |
Opening output for gate motor M2 (fixed leaf) |
8 |
CH |
Closing output for gate motor M1 (swing leaf) |
7 |
COM |
Common output for gate motor M1 (swing leaf) |
6 |
AP |
Opening output for gate motor M1 (swing leaf) |
12, 13 |
LC |
Courtesy light output 230 V AC |
21 |
ES |
Electric lock output 12 V AC |
22 |
0 V |
Reference potential output 0 V |
24 |
24 V |
Power supply output + 24 V DC |
25 |
SCA |
Open gate indicator output 24 V |
26 |
PP |
Step-by-step control input (NO) |
27 |
STP |
Stop control input (NC) |
30 |
APP |
Partial opening control input |
31 |
FOT1 |
External photocell input 1 (NC) |
34 |
FOT2 |
Internal photocell input 2 (NC) |
35 |
SC |
Sensitive edge (NC or 8k2) |
36 |
0 V |
Reference potential output (0 V) |
32 |
TMR |
External timer input (NO) |
46 |
AUX1 |
Safety input during opening (NC) |
47 |
0 V |
Reference potential output 0 V |
48 |
CK |
Power supply output for photocell check (+ 24 V DC) |
43, 44 |
CH2 |
Second channel radio output |
42, 41 |
ANT |
Antenna connection |
|
FC-EN |
End-of-travel module connector |
|
RADIO |
Radio Module |