Wiring

alt Connection


Terminal Acronym Description
1, 3 F - N Power supply 230 V AC ± 10% (50-60Hz)
- GND Ground connection
4, 5 LAMP Flashing light output 230 V AC
11 CH Closing output for gate motor M2 (fixed leaf)
10 COM Common output for gate motor M2 (fixed leaf)
9 AP Opening output for gate motor M2 (fixed leaf)
8 CH Closing output for gate motor M1 (swing leaf)
7 COM Common output for gate motor M1 (swing leaf)
6 AP Opening output for gate motor M1 (swing leaf)
12, 13 LC Courtesy light output 230 V AC
21 ES Electric lock output 12 V AC
22 0 V Reference potential output 0 V
24 24 V Power supply output + 24 V DC
25 SCA Open gate indicator output 24 V
26 PP Step-by-step control input (NO)
27 STP Stop control input (NC)
30 APP Partial opening control input
31 FOT1 External photocell input 1 (NC)
34 FOT2 Internal photocell input 2 (NC)
35 SC Sensitive edge (NC or 8k2)
36 0 V Reference potential output (0 V)
32 TMR External timer input (NO)
46 AUX1 Safety input during opening (NC)
47 0 V Reference potential output 0 V
48 CK Power supply output for photocell check (+ 24 V DC)
43, 44 CH2 Second channel radio output
42, 41 ANT Antenna connection
FC-EN End-of-travel module connector
RADIO Radio Module